First, fire rescue cushions cautiously uses, jumped to avoid induction. If the fire is in effect laying cushion jumped to encourage the masses, it will give rise to three very serious problem: First, the masses may be in the inflatable air cushion has not yet been completed before jumping down, and the direct impact to the ground, causing more serious injuries; The second is to see air cushion after the first to jump down, the people there was not enough time to jump from Air Cushion, who has been dancing after falling to the collision with the end of all the people who leapt against the cushion, the more serious casualties The third is based on tests from the ground from 15 to 20 meters air-cushion escape is the limit (about six floors below), and set fire air-cushion, not only demands the sixth floor of the following personnel can jump, the seventh floor above the masses If you see the same cushion will jump down on the vulnerable to impact or not accurate landed on the cushion and caused casualties, it would be wholly inappropriate use of fire rescue air cushion rescue.
The scene is set in the spring air cushion the earliest. I am Fire fighting squadron shortage of policemen, the fire in the spring, is considered the first organizations to fight the fire immediately, and rescue trapped people. Fire escape because of the very limited time (based on research in the fire room, from Inflatable Obstacles the fire to burn only need a comprehensive six minutes), in such a short period of time, consider first installed rescue cushion is not a realistic idea, pending completion of inflatable air cushion require time, air-cushion too lenient, after the completion of the inflatable, easy waves, and the whole process at least five people at the same time operation, coupled with the fire brigade dispatched need time, simply too late. Therefore, we have to cautiously uses air cushion lifesaving not lead the masses to wait for the laying of air cushion, and the opportunity to escape delays they cause more serious injuries. In addition, when people jumped, the existing steel windows to the proliferation of space everywhere is full of obstacles fell, the masses can be accurately landed on the cushion? Clearly, the scene of the fire in a rapidly changing our commanders to keep a clear head, the situation and reasonable application of fire-fighting tactics, accurate play lifesaving equipment such as air-cushion effect.
Third, we should conscientiously do a good job of the day-to-day maintenance of air-cushion, and inspection work. August 29, 2006, the Ministry of Public Security Technology Oversight Committee approved the GA631-2006 release "Fire rescue cushions," fire-rescue cushions divided into ordinary fire rescue cushions and gas Columnar fire rescue cushions. "Fire rescue cushion" standards for the fire rescue cushion models, technical requirements, test methods, the use of storage, routine inspections and testing rules. Fire rescue cushion products because of the special nature of its clearly defined standards only for emergency rescue and fire-fighting units without any other alternative methods can be used, rescue height of not more than 16 meters. Every three months should be removed Inflatable Obstacles inflatable inspections, with 50 kilograms of ballast from the height of 12 meters to put three tests, routine inspections of prohibited by the staff jumps. So fire fighters in the day-to-day inspection, maintenance in strict accordance with the above requirements to operate, must not be careless or cause accidents.